Back to Top

1
Hi, Guest!
  • Conductivity Meter with ATC Benchtop - HI2315

Conductivity Meter With ATC Benchtop - HI2315

Update Terakhir
:
06 / 12 / 2019
Min. Pembelian
:
1 Buah

Harga

CALL
Hanna Instruments merupakan produk yang dapat menjaga kualitas air sesuai dengan yang anda butuhkan.
Jika anda membutuhkan pH, EC/TDS, Chlorine, Turbidity dan lain - lain kami akan berikan rekomendasi alat yang cocok kepada anda.
Kami memberikan garansi untuk setiap alat yang kami tawarkan dan layanan purna jual.
Silahkan hubungi kami sekarang.

Detail Conductivity Meter With ATC Benchtop - HI2315

The HI2315 is a durable benchtop meter that measures conductivity in four different ranges. The meter utilizes a four-ring potentiometric conductivity probe with platinum sensors to offer versatility over typical amperometric designs. By utilizing the four-ring probe, it is possible to measure very low or very high conductivity levels without having to change probes. The HI2315 also offers automatic temperature compensation and an adjustable temperature coefficient (β).

 

Four EC Measurement Ranges

 

Automatic Temperature Compensation

 

Built-in Solution Holders

 
 

Details

The HI2315 is a basic and affordable conductivity benchtop meter that comes with a four-ring potentiometric EC probe with a built-in temperature sensor. Operation of the meter is simplified to calibration, range selection, and adjustment of the temperature compensation coefficient.

EC calibration is made simple through the easy-to-operate front panel knobs for adjustment. A front knob is also provided to manually set the temperature compensation coefficient of EC from 0 to 2.5 %/°C.

 

Features at-a-glance

Simple User Interface - Operation is simple with limited features that only require the use of a couple of buttons. Readings are easy to view on the large, clear display.

Calibration – Manual EC calibration can be performed at 1 point. A large front panel knob allows for simple, user-friendly calibration of the HI2315 benchtop meter.

Four-ring EC Probe – The HI2315 meter is supplied with the HI76303 platinum, four-ring EC probe with a built-in temperature sensor that operates over a wide range from 0.00 μS/cm to 199.9 mS/cm with a full-scale accuracy of ±1%.

Temperature Compensation - Temperature is automatically compensated for from 0 to 50°C. The temperature correction coefficient, also referred to as β, is adjustable from 0 to 2.5 %/°C for EC measurements.

Built-in Solution Holders - The HI2315 benchtop meter features four solution holders built directly into the casing. This convenient feature saves valuable benchtop space and maintains solution bottles in an upright position, avoiding any potential spills.

 

EC Specifications

EC Range EC Resolution EC Accuracy (@25ºC/77ºF) EC Calibration EC Temperature Compensation
0 to 1999 μS/cm, 0.0 to 199.9 mS/cm, 0.0 to 199.9 μS/cm, 0.00 to 19.99 mS/cm
0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm
±1% FS (excluding probe error)
manual, one point
automatic, 0 to 50°C (32 to 122°F) with β adjustable coefficient from 0 to 2.5 %/°C

Additional Specifications

Electrode/Probe Environment Power Supply Dimensions Weight Ordering Information Warranty
HI76303, platinum four-ring conductivity probe with internal temperature sensor, DIN connector and 1 m (3.3’) cable (included)
0 to 50°C (32 to 122°F), RH max 95% non-condensing
12 VDC adapter (included)
235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)
1.3 kg (2.9 lbs.)
HI2315 is supplied with HI76303 conductivity probe, 12 VDC adapter, and instruction manual.
2 years (probe 6 months)
Tampilkan Lebih Banyak
Kontak Kami